Static voltage stabilizer-SVS

2-50kVA (1/1), 10-3200kVA (3/3)

Static voltage stabilizer for industrial environments like very dusty conditions, humidity and vibration.

More details

Add to wishlist

  • Description

  • Download

  • Specifications

Applications

Specifications

  • 2kVA - 3200kVA with single phase and three phase outputs
  • All industrial voltage value (208-380-400-415-480-600V)
  • Wide input voltage range -65% / +45%
  • Maintenance-free new technology with Microprocessor controller
  • High speed regulation (Up to 500V/sec.)
  • High Efficiency (97%)
  • CPU controlled thyristor units for power management
  • Protection against over load, over temperature, high voltage, low voltage etc.
  • Manual by-pass 
  • For industrial environments like very dusty conditions, humidity and vibration
  • Maintenance free design
  • Minimal size, long life
  • User friendly, easy and comprehensive LCD Display and mimic diagram
  • Parallel connection for special high power applications
  • Self test facility

SVS 2-50kVA Single Phase,10-120kVA Three Phase

Power (kVA)2357,510152030405010152330456075100120
Power range0,8
• Input
Voltage220V/230V AC Single phase+neutral380V/400V AC three phase+neutral
Voltage tolerance-15/-25/-35/-50%, +15%
Frequency50Hz +/-5% (optional 60Hz)
Input connectionCopper busbar terminalScrewed terminal
• Output
Voltage220V/230V AC Single phase+neutral380V/400V AC three phase+neutral
Voltage tolerance+/-3/2/1/0,5%
Frequency50Hz +/-5% (optional 60Hz)
Current(A)811192837557311014518213192837557391122145
Overload capacity101%-125%  3 min. 126%-150% 10 sec. 151%  load  0,2 sec. after then output shut-off
Response time20 msec
Correction speed500V/sec
Efficiency> 97% typical
Output connectionCopper busbar terminalScrewed terminal
LCD displayInput voltage value, output voltage value, output load percent/each phase, output frequency, stabilizer condition and failure Info, warnings
CommunicationRemote management system (network), the ability of monitoring and management (optional)
• Protection
Input voltageStabilizer shut off electronically under / over voltage
Output voltageStabilizer shut off electronically under / over voltage
Input currentMCBMCCBMCBMCCB
Output currentMCBMCCBMCBMCCB
Output overloadStabilizer shut off, 101-125% 3 min, 126-150% 10 sec, 151% load 0,2sec, after then output shut-off
Over temperatureStabilizer shut off for over-temperature
Manual By-pass(ı-0-ıı ) position manual By-Pass switch for failure and maintenance
Surge arresterSuitable surge arrester unit for lightning and high voltage (optional)
• Environment
Operating T°-10°C to +40°C
Altitude< 3000m
Humidity90% without condensing
Accoustic noise<45dB<50dB<55dB
• Specification
TypeIndoor
Protection classIP21
ColorRAL7035
BaseWheel/plinth
CoolingAir forced fans
Dimensions (WxDxH)cm20x41x3727x45x4631x52x52

33x

76x

76

33x76x7650x70x130

60x

60x

150

Weight kg23253035404585100140160100115125140150200240280350

SVS 150-400kVA Three Phase

SVS150SVS200SVS250SVS300SVS400
Power (kVA)150200250300400
Power range0,8
• Input
Voltage380V/400V AC Three Phase + Neutral
Voltage tolerance-15/-25/-35/-50%, +15%
Frequency50Hz +/-5% (optional 60Hz)
Input connectionScrewed terminal
• Output
Voltage380V/400V AC Three Phase + Neutral
Voltage tolerance+/-3/2/1/0,5%
Frequency50Hz +/-5% (optional 60Hz)
Current(A)182245300365485
Overload capacity101%-125%  3 min. 126%-150% 10 sec. 151%  load  0,2 sec. after then output shut-off
Response time20 msec
Correction speed500V/sec
Efficiency> 97% typical
Output connectionScrewed terminal
LCD displayInput voltage value, output voltage value, output load percent/each phase, output frequency, stabilizer condition and failure Info, warnings
CommunicationRemote management system (network), the ability of monitoring and management (optional)
• Protection
Input voltageStabilizer shut off electronically under / over voltage
Output voltageStabilizer shut off electronically under / over voltage
Input currentMCCB
Output currentMCCB
Output overloadStabilizer shut off, 101-125% 3 min, 126-150% 10 sec, 151% load 0,2sec, after then output shut-off
Over temperatureStabilizer shut off for over-temperature
Manual By-pass(ı-0-ıı ) position manual By-Pass switch for failure and maintenance
Surge arresterSuitable surge arrester unit for lightning and high voltage (optional)
• Environment
Operating T°-10°C to +40°C
Altitude< 3000m
Humidity90% without condensing
Accoustic noise<60dB
• Specification
TypeIndoor
Protection classIP21
ColorRAL7035
BaseWheel/plinth
CoolingAir forced fans
Dimensions (WxDxH)cm80x90x14080x90x16090x100x160
Weight kg5006007008001000

SVS 500-3200kVA Three Phase

SVS500SVS600SVS700SVS800SVS900SVS1000SVS1250SVS1600SVS2000SVS2500SVS3200
Power (kVA)500600700800900100012501600200025003200
Power range0,8
• Input
Voltage380V/400V AC Three Phase + Neutral
Voltage tolerance-15/-25/-35/-50%, +15%
Frequency50Hz +/-5% (optional 60Hz)
Input connectionScrewed terminal
• Output
Voltage380V/400V AC Three Phase + Neutral
Voltage tolerance+/-3/2/1/0,5%
Frequency50Hz +/-5% (optional 60Hz)
Current(A)6107308509701100122015001950254030503050
Overload capacity101%-125%  3 min. 126%-150% 10 sec. 151%  load  0,2 sec. after then output shut-off
Response time20 msec
Correction speed500V/sec
Efficiency> 97% typical
Output connectionScrewed terminal
LCD displayInput voltage value, output voltage value, output load percent/each phase, output frequency, stabilizer condition and failure Info, warnings
CommunicationRemote management system (network), the ability of monitoring and management (optional)
• Protection
Input voltageStabilizer shut off electronically under / over voltage
Output voltageStabilizer shut off electronically under / over voltage
Input currentMCCB with motor
Output currentMotorized MCCB (optional)
Output overloadStabilizer shut off, 101-125% 3 min, 126-150% 10 sec, 151% load 0,2sec, after then output shut-off
Over temperatureStabilizer shut off for over-temperature
Manual By-pass(ı-0-ıı ) position manual By-Pass switch for failure and maintenance
Surge arresterSuitable surge arrester unit for lightning and high voltage (optional)
• Environment
Operating T°-10°C to +40°C
Altitude< 3000m
Humidity90% without condensing
Accoustic noise<60dB<65dB
• Specification
TypeIndoor
Protection classIP21
ColorRAL7035
BaseWheel/plinth
CoolingAir forced fans
Dimensions (WxDxH)cm90x120x170240x80x170250x100x170

290x

125x

170

300x

125x

220

330x

125x

220

Weight kg11001300150019002100230027003100350040005000